Contact For Lead Time
SIG200-0A0G12200 SIG200 Sensor Integration Gateway, IO-Link, USB, Ethernet, REST API (1102605)
$594.47 inc. GST
As part of the SICK AppSpace eco-system, the Sensor Integration Gateway (SIG) product family allows the seamless integration of sensor data and enables customizable application solutions based on the SOPAS ET technology. Digital input and output signals or IO-Link signals can be bundled easily via the ports on the SIG200 Sensor Integration Gateway and then linked to form a customized sensor-actuator system using the drag & drop function in the logic editor. The collected data can therefore be merged and transmitted to higher-level systems, including in the context of Industry 4.0.
Features
• 4 configurable IO-Link master ports (standard I/O or IO-Link)
• Easy parameterization via USB or Ethernet thanks to intuitive SOPAS ET user interface
• “Dual Talk”: Access to sensor data from the company level and in parallel via industrial Ethernet
• Solution of complex application tasks with the logic editor
| I/O connection |
4 x M12, 5-pin female connector, A-coded |
| Connection Configuration |
1 x M8, 4-pin female connector, USB 2.0 (USB-A) |
| Logic editor |
Yes |
| Communication interface |
IO-Link, USB, Ethernet, REST API |
| Further Functions |
Web server available, USB connection for easy configuration of the SIG200 Sensor Integration Gateway with SOPAS ET, the engineering tool from SICK, logic editor is available for easy configuration of logic functions |
Contact For Lead Time
Description
Product Description
• 4 configurable IO-Link master ports (standard I/O or IO-Link)
• Easy parameterization via USB or Ethernet thanks to intuitive SOPAS ET user interface
• “Dual Talk”: Access to sensor data from the company level and in parallel via industrial Ethernet
• Solution of complex application tasks with the logic editor
Mechanics & Electronics
| Connections |
|
| IO-Link |
4 x M12, 5-pin female connector, A-coded |
| Power |
1 x M12, 4-pin plug, A-coded |
| CONFIG |
1 x M8, 4-pin female connector, USB 2.0 (USB-A) |
| Ethernet |
2 x M12, 4-pin female connector, D-coded |
|
| Supply voltage |
10 V DC … 30 V DC 1) |
| Current consumption |
|
| Power Port |
≤ 175 mA (At supply voltage 24 V DC) 2) |
|
≤ 3,000 mA 3) |
|
| Input/output characteristics |
|
| S1-S4 pin 1 voltage supply |
≤ 500 mA |
| S1-S4 pin 4 output current |
≤ 200 mA 4) |
| Power Port pin 4 output voltage HIGH |
VH ≥ VUS – 3 V |
| S1-S4 pin 2 input voltage |
Type 3 IEC 61131-2 |
| S1-S4 pin 4 input voltage |
Type 1 IEC 61131-2 |
|
| Enclosure rating |
IP67 |
| Protection class |
III |
| Housing material |
Zinc |
| Housing color |
Light blue/Black |
| Weight |
520 g |
| Dimensions (L x W x H) |
213.9 mm x 57 mm x 38.3 mm |
| UL File No. |
E497722 |
Interfaces
| Communication interface |
IO-Link, USB, Ethernet, REST API |
|
| Logic editor |
✔ |
| Web server |
✔ |
| IO-Link Master |
|
| Function |
The SIG200 Sensor Integration Gateway is an IO-Link master with 4 configurable ports to which IO-Link device as well as binary switching sensors and actuators can be connected. The gateway data is made available to a PLC or cloud application via the REST API.
SIG200 can also be operated as a standalone system by directly configuring simple logic functions across several connected devices via the SOPAS ET user interface. |
| IO-Link version |
V1.1, V1.0 |
| Port Class |
A |
| Number of IO-Link ports |
4 |
| Transmission type |
COM1, COM2, COM3 |
|
| Operator interfaces |
SOPAS ET, the engineering tool for configuration via USB, Additionally, the SIG200 can be configured via the integrated webserver. Default IP adress: 192.168.0.1 |
| MAC address |
See product label |
| Number of inputs |
Max. 8 x PNP, type 1 or 4 x IO-Link |
| Number of outputs |
Max. 4 x PNP |
| Max. Output frequency |
50 Hz |
| Inputs/outputs |
|
| S1-S4 |
4 configurable ports
Pin4 can be used in one of the available port modes: IO-Link, digital input or digital output.
An additional digital input signal can be connected using Pin2. |
| LINK/ACT 1 & 2 |
Two Ethernet ports are provided for the network connection |
| CONFIG |
Port for configuration via USB with SOPAS ET (SOPAS ET can be downloaded for free from www.sick.com) |
|
| Optical indicators |
4 LED green (To the IO-Link ports, Pin4 (C/DI/DO))
4 Yellow LED (To the IO-Link ports, Pin2 (DI))
2 LED green (To the Ethernet ports)
1 LED green (For the Power Port)
1 LED green |
| Initialization time after switch on |
60s (plus additional time for IODD installation) |
| Scope of delivery |
SIG200-0A0G12200, 4x blind plugs (M12) on port S2, S3, S4, P2, 1x blind plug (M8) on port CONFIG, 20 port labels, quickstart |
Reviews