Product Description
Model | Sensor including system plug |
Application | Indoor |
Protective field range | 9 m |
Warning field range | 64 m |
Number of simultaneously monitored fields | ≤ 4 1) 2) |
Number of fields | 8 3) |
Number of monitoring cases | 2 |
Scanning angle | 275° |
Resolution (can be configured) | 30 mm
40 mm 50 mm 60 mm 70 mm 150 mm 200 mm |
Angular resolution | 0.1° |
Response time | ≥ 90 ms |
Protective field supplement | 100 mm |
1) Protection, warning or contour detection fields.
2) Please note the number of available OSSD pairs.
3) Please note the number of available inputs and OSSD pairs.
Type | Type 3 (IEC 61496) |
Safety integrity level | SIL2 (IEC 61508) |
Category | Category 3 (EN ISO 13849) |
Performance level | PL d (EN ISO 13849) |
PFHD (mean probability of a dangerous failure per hour) | 8.0 x 10-8 (EN ISO 13849) |
TM (mission time) | 20 years (EN ISO 13849) |
Safe state in the event of a fault | At least one OSSD is in the OFF state. |
Restart interlock | ✔ |
External device monitoring (EDM) | ✔ |
Multiple sampling | ✔ |
Monitoring case switching | ✔ |
Simultaneous monitoring | ✔ |
Static protective field switching | ✔ |
Safe contour detection | ✔ |
Contour as a reference | ✔ |
Integrated configuration memory | ✔ |
Measured data output | None |
|
|||||
Universal I/Os | 3 | ||||
|
|||||
Configuration method | PC with Safety Designer (Configuration and Diagnostic Software) | ||||
|
|||||
Display elements | Graphic color display, LEDs |
Protection class | III (EN 61140) |
Supply voltage Vs | 24 V DC (16.8 V DC … 30 V DC) |
Power consumption | 7 W (without output load) |
Dimensions (W x H x D) | 112 mm x 135.1 mm x 111.1 mm |
Weight | 1.15 kg |
Housing material | Aluminum |
Housing color | RAL 1021 (yellow), RAL 9005 (black) |
Optics cover material | Polycarbonate |
Optics cover surface finish | Outside with scratch-resistant coating |
Enclosure rating | IP65 (IEC 60529) |
Ambient operating temperature | –10 °C … +50 °C |
Storage temperature | –25 °C … +70 °C |
Vibration resistance | 5 g, 60 Hz … 150 Hz (IEC 60068-2-6, IEC 61496-1, IEC 61496-3) |
Shock resistance | 10 g, 16 ms (IEC 60068-2-27, IEC 61496-3) |
Type of light | Pulsed laser diode |
Wave length | 845 nm |
Detectable remission | 1.8% to several 1000% |
Laser class | 1M (21 CFR 1040.10 and 1040.11, IEC 60825-1) |